Browse Source

fix: Avoid incorrect reload of the commutation wait timer

The bug affected wait when setting motor timing to high
main
Mathias Rasmussen 4 years ago
parent
commit
a480fbfdbd
  1. 11
      Bluejay.asm

11
Bluejay.asm

@ -2276,19 +2276,22 @@ comp_exit:
;
; Setup commutation timing routine
;
; Sets up and starts wait from commutation to zero cross
; Clear the zero cross timeout and sets up wait from zero cross to commutation
;
;**** **** **** **** **** **** **** **** **** **** **** **** ****
setup_comm_wait:
clr IE_EA
anl EIE1, #7Fh ; Disable timer 3 interrupts
; It is necessary to update the timer reload registers before the timer registers,
; to avoid a reload of the previous values in case of a short Wt_Comm_Start delay.
mov TMR3RLL, Wt_Adv_Start_L ; Setup next wait time
mov TMR3RLH, Wt_Adv_Start_H
mov TMR3CN0, #00h ; Timer 3 disabled and interrupt flag cleared
mov TMR3L, Wt_Comm_Start_L
mov TMR3H, Wt_Comm_Start_H
mov TMR3CN0, #04h ; Timer 3 enabled and interrupt flag cleared
; Setup next wait time
mov TMR3RLL, Wt_Adv_Start_L
mov TMR3RLH, Wt_Adv_Start_H
setb Flag_Timer3_Pending
orl EIE1, #80h ; Enable timer 3 interrupts
setb IE_EA ; Enable interrupts again

Loading…